CONDUCTOR: Stranded tinned-coated copper.
VOLTAGE: 600 V.
TEMPERATURE: 105° C.
COLOR: White.

CONSTRUCTION:

    M5086/1 - Polyvinylchloride insulated, nylon jacket.
    M5086/2 - Polyvinylchloride insulated, glass braid, nylon jacket. Sizes 10 AWG and greater have braid with lacquer.

USES: Excellent resistance to abrasion, cold, moisture, fungus, solvents and flame.

Note: MIL-DTL-5086/1 Basic Wire Specification: A
Note: MIL-DTL-5086/2 Basic Wire Specification: B




Request InformationCompare Items   Results per Page : 
  Results 1 - 23 of 23 1 

Catalog No.

Mil. Spec.

AWG Size

Stranding

Max. Resistance @ 20°C (@ 68°F)

Diameter

Weight

107- 1 M5086/1 22 19/34 16.2 Ohms/1000 ft
53.1 Ohms/km
0.068 in
1.73 mm
4.40 lbs/1000 ft
6.55 kgs/km
107- 2 M5086/1 20 19/32 9.88 Ohms/1000 ft
32.4 Ohms/km
0.078 in
1.98 mm
6.30 lbs/1000 ft
9.37 kgs/km
107- 3 M5086/1 18 19/30 6.23 Ohms/1000 ft
20.4 Ohms/km
0.088 in
2.24 mm
8.60 lbs/1000 ft
12.8 kgs/km
107- 4 M5086/1 16 19/29 4.81 Ohms/1000 ft
15.8 Ohms/km
0.098 in
2.49 mm
10.70 lbs/1000 ft
15.92 kgs/km
107- 5 M5086/1 14 19/27 3.06 Ohms/1000 ft
10.0 Ohms/km
0.117 in
2.97 mm
16.40 lbs/1000 ft
24.40 kgs/km
107- 6 M5086/1 12 37/28 2.02 Ohms/1000 ft
6.63 Ohms/km
0.137 in
3.48 mm
24.70 lbs/1000 ft
36.75 kgs/km
107- 7 M5086/1 10 37/26 1.26 Ohms/1000 ft
4.13 Ohms/km
0.159 in
4.04 mm
36.50 lbs/1000 ft
54.31 kgs/km
107- 1A M5086/2 22 19/34 16.20 Ohms/1000 ft
53.1 Ohms/km
0.075 in
1.91 mm
4.70 lbs/1000 ft
6.99 kgs/km
107- 2A M5086/2 20 19/32 9.88 Ohms/1000 ft
32.4 Ohms/km
0.085 in
2.16 mm
6.80 lbs/1000 ft
10.1 kgs/km
107- 3A M5086/2 18 19/30 6.23 Ohms/1000 ft
20.4 Ohms/km
0.095 in
2.41 mm
9.50 lbs/1000 ft
14.1 kgs/km
107- 4A M5086/2 16 19/29 4.81 Ohms/1000 ft
15.8 Ohms/km
0.105 in
2.67 mm
11.90 lbs/1000 ft
17.71 kgs/km
107- 5A M5086/2 14 19/27 3.06 Ohms/1000 ft
10.0 Ohms/km
0.125 in
3.18 mm
18.30 lbs/1000 ft
27.23 kgs/km
107- 6A M5086/2 12 37/28 2.02 Ohms/1000 ft
6.63 Ohms/km
0.143 in
3.63 mm
26.0 lbs/1000 ft
38.7 kgs/km
107- 7A M5086/2 10 37/26 1.26 Ohms/1000 ft
4.13 Ohms/km
0.189 in
4.80 mm
44.0 lbs/1000 ft
65.5 kgs/km
107- 8A M5086/2 8 133/29 0.701 Ohms/1000 ft
2.30 Ohms/km
0.240 in
6.10 mm
70.0 lbs/1000 ft
104 kgs/km
107- 9A M5086/2 6 133/27 0.455 Ohms/1000 ft
1.49 Ohms/km
0.293 in
7.44 mm
110.0 lbs/1000 ft
163.7 kgs/km
107- 10A M5086/2 4 133/25 0.280 Ohms/1000 ft
0.919 Ohms/km
0.355 in
9.02 mm
165.0 lbs/1000 ft
245.5 kgs/km
107- 11A M5086/2 2 665/30 0.183 Ohms/1000 ft
0.600 Ohms/km
0.425 in
10.8 mm
250.0 lbs/1000 ft
372.0 kgs/km
107- 12A M5086/2 1 817/30 0.149 Ohms/1000 ft
0.489 Ohms/km
0.470 in
11.9 mm
305.0 lbs/1000 ft
453.8 kgs/km
107- 13A M5086/2 1/0 1045/30 0.116 Ohms/1000 ft
0.381 Ohms/km
0.525 in
13.3 mm
400.0 lbs/1000 ft
595.2 kgs/km
107- 14A M5086/2 2/0 1330/30 0.091 Ohms/1000 ft
0.299 Ohms/km
0.590 in
15.0 mm
500.0 lbs/1000 ft
744.0 kgs/km
107- 15A M5086/2 3/0 1665/30 0.071 Ohms/1000 ft
0.233 Ohms/km
0.650 in
16.5 mm
620.0 lbs/1000 ft
922.6 kgs/km
107- 16A M5086/2 4/0 2109/30 0.056 Ohms/1000 ft
0.184 Ohms/km
0.720 in
18.3 mm
785.0 lbs/1000 ft
1168 kgs/km
  Results 1 - 23 of 23 1 

 

Site created by ThomasNet Web Solutions, a division of ThomasNet.com
Toll-Free: 800.326.0006The Electronic Wire and Cable Specialist for Over 60 Years